⚠ FIRE ALARM INTERLOCK -- ALL FANS STOPPED -- CONTACT FACILITY MANAGEMENT
Air Movement Control
FanOS
PRO
Acme Manufacturing
Main Warehouse
18Run
4Stop
1Fault
77FTemp
⚡42.6 kW
Normal
9:18 AM
Thu May 21
🌙
Zone Controlx
Temp Sensorsx
Fan Typesx
✏ Edit Mode — Drag fans to reposition · Tap outside to exit
Running
Stopped
Fault
E-Stop
HVLS-03
Zone A — Warehouse
480V · 3Ph · Invertek E3
✕
Running
Temperature
--
Degrees Fahrenheit
Modbus Address--
Zone--
65%
35.8 Hz
0100%
Fan ModeExhaust (Air Out)
Change fan mode in Settings
Relay Control — On / Off Only
RUNNING
This device is relay-activated. No VFD — instant on/off only.
Direction
Live Data
Output Hz35.8 Hz
Voltage480V 3Ph
Current3.4 A
Power2.3 kW
Temp Nearby76°F
Run Time6.2 hrs
Last FaultNone
Device
Modbus Addr3
VFD ModelInvertek E3
Input Voltage480V 3Ph
TypeHVLS Fan
Manufacturer
⛔ EMERGENCY FAULT — LOCKED
Visual inspection and repair required before restart.
Sensor Offline
Possible causes:
· Dead or low battery
· Damaged or loose wiring
· Out of range or interference
· Sensor hardware failure
Log out?
You will return to the login screen
Active Faults
✕
⚡
Starting motors…
Staggered start — 8s between motors
Cancel
Schedule
Automated start/stop times
🌅
Morning Start
Mon-Fri 6:00 AM — All Fans 65%
🌞
Peak Hours
Mon-Fri 12:00 PM — All Fans 100%
🌙
Evening Stop
Mon-Fri 6:00 PM — All Fans OFF
Settings
System configuration
Site Info
Site NameAcme Manufacturing
LocationMain Warehouse
RS-485 Ports
Port 1 Baud9600 8N1
Port 2 Baud19200 8E1
Devices Found31 online
Display
Dark Mode
Poll Interval2 seconds
System
VersionFanOS Pro 1.0
Uptime14d 6h 22m
Settings
✕
Site
Facility Name
Location / Description
Communication
RS-485 Port 1
Invertek / Yaskawa
9600 8N1 ● Online
RS-485 Port 2
Schneider ATV320
19200 8E1 ● Online
Poll Interval2 seconds
Fan Control
Stagger Delay
Delay between motor starts
8 seconds
Max Fan Speed
Maximum Hz output
55 Hz
FA Interlock
Fire alarm input — GPIO 27
● Monitoring
Temperature Control
Auto Speed by Temp
DHT22 sensor on Port 1
Low Speed TriggerBelow 70°F
High Speed TriggerAbove 85°F
Network
Local IP192.168.1.105
WiFi NetworkACME-FLOOR
Remote Access
Cloudflare Tunnel — SaaS
Display
Dark Mode
Kiosk Mode
Auto-launch on boot
System
VersionFanOS Pro 1.0.0
HardwareAAEON UP Xtreme 7100
Uptime14d 6h 22m
Total Fans31 configured
Devices
Device Names
Custom label shown on floor plan. System ID stays the same.
Communication
RS-485 Port/dev/ttyS4
Baud Rate9600 8N1
Bus StatusOnline
Network
Local IP192.168.1.105
WiFi NetworkFacilityNet
System
VersionFanOS Pro 1.0.0
HardwareAAEON UP Xtreme
Uptime14d 6h 22m
Danger Zone
FanOS Pro access only. These actions cannot be undone.
Wall Exhaust Fan Modes
Set during installation -- determines airflow direction
Access PINs
Admin only -- keep these confidential
Fault Diagnostic Guide
Motor Overload
E07
✕
Manufacturer Support
Possible Causes
How to Check & Fix
Safety Notice
Always de-energize the fan and VFD before performing any physical inspection. Lock out / tag out per your facility safety procedures. Do not reset emergency faults remotely — inspect the fan physically first.
Remove Fan
✕
Remove HVLS-03?
This fan will be removed from the floor plan and all zones. The VFD will remain wired but uncontrolled.